

- #Failed to connect to veeam backup & replication server update#
- #Failed to connect to veeam backup & replication server plus#
- #Failed to connect to veeam backup & replication server windows#
%programdata%\Paessler\PRTG Network Monitor\\Logs\sensors Special Thanks: Note!! Using the option “Write EXE result to disk” can be very helpful for debugging. Settings for the EXE/Script Advanced Sensor You can also run the script manually to test it:Īdd an “EXE/Script Advanced” sensor to a device GitHub Gist PRTG Advanced Custom Sensor for VEEAM v9.The latest version of the script can be downloaded from the Github Gist link below: „DisableFirstRunCustomize“=dword:00000001 The Script: Disable IE First-Run (because of “Invoke-WebReques” and “Invoke-RestMethod”).Give the script user rights in Backup Enterprise Manager.%programfiles%\PRTG Network Monitor\Custom Sensors\EXEXML Preparation: %programfiles(x86)%\PRTG Network Monitor\Custom Sensors\EXEXML To create a custom script sensor in PRTG you need to save a script (preferably Powershell) in the following directory on the machine where the script will run (on the core server or on the remote probe): Veeam B & R Monitoring with PRTG – How it Works Using Powershell scripts and the Veeam API you can build comprehensive PRTG sensors, including real-time alerting and reporting on historical data (e.g.
#Failed to connect to veeam backup & replication server plus#
With this additional component you can get central reporting on multiple Veeam Backup & Replication servers.Īnd if you add the Veeam Enterprise Plus Edition, you get a powerful RESTful API for the Backup Enterprise Manager.

#Failed to connect to veeam backup & replication server windows#
Starting with Windows Vista the User Profile Service will force the unloading of a user profile when that user logs off. If this user were to log off of the machine then the user's profile would get unloaded and the COM+ application can no longer read registry keys in the profile of the user identity. The user identity that is associated with the COM+ application is logged on when the COM+ application is first initialized.
#Failed to connect to veeam backup & replication server update#
The above fix seems not solving the problem permanently and, again, the issue is not due to Veeam software but to an update of Azure AD connect.Īfter a Google search, I found this article in the Microsoft website that explains the issue: This simple fix resolved the issue allowing to complete the backup job successfully ensuring the protection of the Azure AD Connect server. This time the backup has completed successfully. When the Azure AD Connect server has rebooted, run the backup job once again.

When the process has completed, the server must be rebooted to complete the procedure. Click Yes to proceed. In the Programs category, click the link Uninstall a program.įrom the programs list, select Microsoft SQL Server 2012 Express LocalDB and click Repair. To solve the problem, login to the Azure AD Connect server and go to the Control Panel. The error reported in the Veeam log file. To get additional details of the problem, opening the log file the error is related to the SQL Server Writer, perhaps a Microsoft update somehow caused the issue.Ī VSS critical writer has failed. for the virtual machine affected by the problem. The backup job window displays the error Failed to call RPC function " Vss.Unfreeze".

The Veeam backup job of Microsoft Azure AD Connect fails with the error A VSS critical writer has failed.
